Reader Communication Protocol Developer's Guide
Boot Firmware
 
The reader runs to the APP Firmware layer. When the reader is in Bootloader layer and receives this command, it executes to the APP Firmware layer. If it is already in the APP Firmware layer, no processing is made and returns successful operation.

Command Attribute

Command Code Bootloader Command App Firmware Command
0x04 Yes Yes

Reader to Host

Format of Data Field
Field Byte Length Description
BootLoader Version 4 bytes The Version of Bootloader
Hardware Version 4 bytes the highest byte indicates the reader type
Firmware Date 4 bytes The Date of building the firmware
Firmware Version 4 bytes The Version of firmware
Supported Protocol 4 bytes Currently always be 0x00000010

Example

Host to Reader
FF 00 04 1D 0C
Header Data Length Command Code CRC
 
Reader to Host
FF 14 04 00 00 13 04 15 00 A8 00 00 01 20 13 05 22 13 05 23 00 00 00 00 10  
Header Data Length Command Code Status Code BootLoader Version Hardware Version Firmware Date Firmware Version Supported Protocol CRC