Reader Communication Protocol Developer's Guide
Get Frequency Hopping
 
This command is used to get the information of frequency hopping and frequency hopping time. The command has two formats for getting the frequency hopping table and regulatory hopping time.

Command Attribute

Command Code Bootloader Command App Firmware Command
0x65 No Yes

Host to Reader


There is no Data filed in host-to-reader command.
 
Get Regulatory Hopping Time

Format of Data Field
Field Byte Length Description
Option 1 byte Must be 0x01

Reader to Host


Format of Data Field
Field Byte Length Description
frequencies M*4 bytes M frequencies, each frequency is 4 bytes length.
 
Get Regulatory Hopping Time

Format of Data Field
Field Byte Length Description
Option 1 byte Must be 0x01
Hop time 4 bytes Frequency hopping time, in milliseconds

Example

Example 1

 
Reader to Host
FF 0C 65 00 00 00 0D F9 26 00 0D C8 52 00 0E 24 1E 2C B5
Header Data Length Command Code Status Code 915250KHZ 903250KHZ 926750KHZ CRC
  
Example 2

Get Regulatory Hopping Time
  
Host to Reader
FF 01 65 01 B9 BC
Header Data Length Command Code Option CRC
Reader to Host
FF 05 65 00 00 01 00 00 01 90 4B 6C
Header Data Length Command Code Status Code Option Hop time CRC