Reader Communication Protocol Developer's Guide
Set Current Region
 

Command Attribute

Command Code Bootloader Command App Firmware Command
0x97 No Yes

Host to Reader

Format of Data Field
Field Byte Length Description
Region Code 1 byte Please refer to the Region Code Table
 
Regin Code Table
Region Name Region Code
North America(902-928) 0x01
China 1(920-925) 0x06
European(865-867) 0x08
China 2(840-845) 0x0A
Full Frequency Band(840-960) 0xFF

Example

Set region to NA
  
Host to Reader
FF 01 97 01 4B BC
Header Data Length Command Code Region Code CRC

Remark

The hop table of different region can only contain certain specific frequencies in the table below except Full Frequency Band. So Set Frequency Hopping command can only select the frequencies which belong to the region which the reader is working on. The Full Frequency Band can uses any frequency in 840-960MHZ. The frequencies in Region Frequencies Table is the default hop table for each region after using the Set Current Region command.
 
Region Frequencies Table
Region Frequencies(KHZ)
North America(902-928) 915750, 915250, 903250, 926750, 926250, 904250, 927250, 920250, 919250, 909250, 918750, 917750, 905250, 904750, 925250, 921750, 914750, 906750, 913750, 922250, 911250, 911750, 903750, 908750, 905750, 912250, 906250, 917250, 914250, 907250, 918250, 916250, 910250, 910750, 907750, 924750, 909750, 919750, 916750, 913250, 923750, 908250, 925750, 912750, 924250, 921250, 920750, 922750, 902750, 923250
China 1(920-925) 921375, 922625, 920875, 923625, 921125, 920625, 923125, 921625, 922125, 923875, 921875, 922875, 924125, 923375, 924375, 922375
European(865-867) 865700, 866300, 866900, 867500
China 2(840-845) 841375, 842625, 840875, 843625, 841125, 840625, 843125, 841625, 842125, 843875, 841875, 842875, 844125, 843375, 844375, 842375
Full Frequency Band(840-960) 840000, 850000, 860000, 870000, 880000, 890000, 900000, 910000, 920000, 930000, 940000, 950000, 960000